You are here:>>Drok
Drok

Forum Replies Created

Viewing 15 posts - 1,276 through 1,290 (of 2,965 total)
  • Author
    Posts
  • Drok
    Keymaster
    Post count: 2971

    Hello Mario,

    Thanks for writing in.

    To prevent  battery from feeding back, you can add diode at the output.

    We are sorry we don’t have step-by-step instructon for this usage.

    Regarding to connection and setting, please kindly refer to this instruction https://images-na.ssl-images-amazon.com/images/I/C1QIs1zApZS.pdf

    Hope it can help you.

    Best regards.

    Drok
    Keymaster
    Post count: 2971
    in reply to: just reads zero #30244

    Hello John Rich,

    Thanks for writing iN.

    Would you please tell us which item it is?

    To check problem for you, could you please take some images to show  wiring and other details?

    Best regards.

    • This reply was modified 7 years, 6 months ago by  Drok.
    Drok
    Keymaster
    Post count: 2971
    in reply to: shunt #30228

    Hello paul maxey,

    Thanks for writing in.

    It seems your wiring is wrong. Maybe you can refer to our other meter’s wiring. https://www.amazon.com/dp/B017BDQHE6

    Any more questions, please let us know

    Best regards.

    Drok
    Keymaster
    Post count: 2971

    Hello Michael J Verbree,

    Thanks for writing in.

    100405 CT and 100372 CT can be interchanged.

    Best regards.

    Drok
    Keymaster
    Post count: 2971

    Hello Michael Verbree,

    Thanks for writing in.

    The label should be correct, would you please take some images to show how it is and your wiring?

    If you are not sure how to upload images here, pleaes kindly send it to service@droking.com

    Best regards.

    Drok
    Keymaster
    Post count: 2971

    Hello StinkyVoltz,

    Thanks for sharing your soluiton here. It should help someone.

    Best regards.

     

    Drok
    Keymaster
    Post count: 2971

    Hello Philip Dara,

    Thanks for writing in.

    We find your  question on the other part” Contact us”, and we have replied there.

    Any more questions, please let us know.

    Best regards.

    Drok
    Keymaster
    Post count: 2971

    Hello Wayne,

    Please kindly refer to the following image.

    200139

    Best regards.

    Drok
    Keymaster
    Post count: 2971
    in reply to: product data #30215

    Hello william white,

    Thanks for your order.

    We are sorry we can’t confirm the item, would you please send us product link or ASIN number?

    Best regards.

    Drok
    Keymaster
    Post count: 2971

    Hello StinkyVoltz,

    When AC power is restored, if output is normal (no zero ouput),  that means it is normal.

    Output votlage from battery and AC power is different, when  switch, it may cause voltage varies.

    Best regards.

    Drok
    Keymaster
    Post count: 2971

    Hello StinkyVoltz,
    Thanks for writing in.
    when AC power is restored, did you check whether there is output? And how is it when connect  other load?
    Best regards,

    DROK

    Drok
    Keymaster
    Post count: 2971
    in reply to: missing screws #30204

    Hello  mike dzuba,

    Thanks for writing in.

    We are sorry we can’t confirm which item you mean. Would you please send us product link?

    Best regards.

    Drok
    Keymaster
    Post count: 2971

    Hello Marc Imerone,

    Thanks for writing in.

    We have two AC 80-260v meters, so we are not sure which one is correct.

    200123

    200071

    It’s regretted both of them don’t have outdoor version. It’s better not to extend wire, which may have influence on measurement.

    Any more questions, please let us know.

    Best regards.

    Drok
    Keymaster
    Post count: 2971

    Hello Duane M Reese,

    Thanks for writing in.

    The left one is high voltage alarm, the right one is low votlage alarm.

    From hight voltage value to low voltage value, there are 6 digits of number, you can short press button to increase them. Without button operation  for over 3 seconds, it will switch to next digit.

    After setting, please keep pressing button until it show” PASS”.

    Hope this can help you.

    Best regards.

    Drok
    Keymaster
    Post count: 2971
    in reply to: Input Impedance #30194

    Hello Ron,

    Thanks for your support on our product.

    However, we ar sorry we don’t have meter with 1 meg ohm input impedance. Please forigve us.

    For any more questions, please let us know.

    Best regards.

Viewing 15 posts - 1,276 through 1,290 (of 2,965 total)