Forum Replies Created
-
AuthorPosts
-
in reply to: 200326 DC-DC Buck converter UART #28261
Hello mahsa,
Item#200326 doesn’t have UART, so we don’t have communication protocol manual for it.
Best regards.in reply to: 200310 DC-DC Buck converter UART #28260Hello ron,
ru command(read the actual output voltage)
The format is: aru+0x0d+0x0a
For example, #ru00000000488 it means the actual output voltage is 4.88V
ri command (read the actual output current)
The format is: ari+0x0d+0x0a
For example, #ri00000000087, it means the actual output current is 0.87A
Best regards.in reply to: DROK 4-20mA Signal Generator, DC 12-30V #27834Hello K Williams,
It is easy to hook up. Please see the following diagram. This signal generator is connected in series with power supply and load.

Best regards.in reply to: Datasheet of Board YFKP15 #27759Hello Dieter Stotz,
Thanks for writing in.
But we are sorry YFKP15 is not ASIN number or SKU, we can’t ensure the item you mean.
Would you please find out the ASIN in your order or send us the product link for confirmation?
Best regards.Hello Eric Frey,
We are sorry for inconvenience caused on you.
Did you hook it up like the following diagram?

300456
Best regards.Hello Ken,
Are you talking about 200193?
Please kindly follow the diagram in instruction. Any questions, please feel free to let us know.
Best regards.in reply to: DROK® AC 80-260V Digital Multimeter #26258Hello Muhammed Yasir,
Thanks for writing in.
Please can you confirm if it is this one?
200122
How is it when test large current?
Best regards.in reply to: DROK® DS18B20 Temperature Sensor #26257Hello ACMast,
Thanks for writing in.
DS18820 is digital temperature sensor, NTC is Analog temperature sensor. So we are not sure if it is suitable for your application. It’s better choose the same type.
Best regards.in reply to: current calibration for DK50V5A #26216Hello Roberto,
Thanks for reply. Base on these information, please try the zero calibration.
Firstly, please press and hold the SET button without any load, then power the meter. When it displays main window, please release button. After that, zero calibration is finished.
Best regards.in reply to: DROK® TDA8920 Subwoofer #26210Hello Roberto,
We want to search more information about your Yamaha RX-V481D so that we can offer solution for you. However, we are sorry the information we can get is little. If you have any more product information or instruction. Would you please share with us?
Best regards.in reply to: DROK 4-20mA Signal Generator, DC 12-30V #26204Hello K Williams,
Thanks for writing in.
B071CJSVL6 is not a order No, so we can’t find out any information with it.
According to your description, we think it may be this one.300480
Please kindly confrim it.
Best regardsin reply to: current calibration for DK50V5A #26178Hello Jim S,
Would you please tell us how large the output current is without load?
Best regards.in reply to: DROK® TDA8920 Subwoofer #26161Hello Roberto,
Thanks for writing in.
Do you mean connect pre-amplified subwoofer output to the signal input terminal of our item? But there is only one input terminal, we can’t ensure the left or right you mean. If you can, please let us know more detail.
Best regards.in reply to: Raspberry pi controlled voltage regulator #26159Hello Bruce Anthony,
Thanks for writing in.
Would you please let us know which item you mean?please kindly send a product link or ASIN number for confirmation.
Best regards.in reply to: Wiring Diagram for YB5135D Ammeter/Ext Shunt #26116Hello Steve Baker,
Thanks for writing in.
We are sorry for inconvenience caused on you.
Are you talking about this item?300114
The connection is as picture shown:

Best regards. -