in reply to: Dual Display AC Panel meter P/N: D69-2080. #6652
Hello Basil F.,
Thank you for writing in.
Since so many products are with similar module number, it is hard for us to ensure the product just by “D69-2080”.
Could you please tell us your order ID?
With your help, we can find a solution more quickly.
Looking forward to hearing from you.
Best reagrdsin reply to: Grounding 120w power supply converter #6615Hello Rod Cotter,
So sorry for causing you misunderstanding.
We just want you to ensure the vehicle is positive ground.
Your input wiring is right.
Best regardsin reply to: Parallel circuit of energy meter #6614Hello Félix,
You’re welcome.
If you have any queries, please fell free to write back to us.
Best regardsHello Lonny,
So sorry that we do not have a protective shell for this product now.
However, we are trying out best to improve the product.
Beg your understanding.
Best regardsin reply to: Grounding 120w power supply converter #6596Hello Rod Cotter,
Thank you for writing in.
Please ensure that the ground is on positive.
For the output, the yellow wire is connected to the output + and the black wire is connected to output -.
Hope this can help you.
Best regardsin reply to: Wiring of Drok digital multimeter AC 80-260 volts #6595Hello William T. Ward,
Thank you for your reply.
So long as the input voltage for the meter is the power frequency voltage (city power).
Your plan will be Ok.
Best regardsin reply to: Parallel circuit of energy meter #6594Hello Félix,
If the measuring current is over 20A, you should use the 50A module with external shunt.
The shunt should be connected series to the negative of the load.
The value of the shunt is 50A/75mV.
Here is the wiring diagram of the 50A module:

Hope this can help you.
Best regardsin reply to: 8-22V to 1-15V Buck Convertor Info/Datasheet #6588Hello Matthew,
Thank you for writing in.
There is no fuse or capacitor inside the product.
But if the converter is broken, there will be no output from the converter.
The possibility of high voltage output is very little.
And here the PDF file is the datasheet of the product:
DATASHEET_090010
Hope this can help you.
Best regardsin reply to: Drok SKU:180081 #6573Hello Gary Hetrick,
Thank you for your reply.
Could you please send us some images to let us check the problem details?
With your help, we can find a solution more quickly.
You can send the images to us by email (service at droking dot com).
Waiting for your reply.
Best regardsin reply to: Which regulator do you recommend #6572Hello Steve,
Thank you for your interest in our product.
So sorry that we do not have a product can meet your need.
Beg your understanding.
Best regardsin reply to: Product required. #6571Hello Maddog,
Thank you for writing in and your valuable suggestion.
DROK® DC 3-21V Load Battery Tester, 35W 3A Portable USB Monitor, Intelligent Constant Current Electric Discharge Resistance Power Resistor Kit for Power Bank Capacity Testing Support QC2.0/3.0
We have checked that this product is equipped with a LCD display for you to monitor the values of discharging or charging status.
The product also has a heat sink and a fan and the temperature of the board is displayed on the LCD monitor.
Can it meet your need?
Best regardsHello amartin,
Thank you for writing in.
There are two calibrating potentiomentes inside one for ampere calibration and the other for voltage calibration, please check the following image:

If you extend the cable, it will affect the accuracy of the current reading.
So sorry that we do not have a AC meter for AC100-300V-10A.
Beg your understanding and hope this can help you.
Best regardsin reply to: Parallel circuit of energy meter #6568Hello Félix,
Yes, the product can work for your application but the operating values and the measuring values of your application should be within the values of the product.
Here are the parameters of the product:
Parameters:
Working Voltage: 6.5 ~ 100VDC
Measuring Range: 6.5 ~ 100VDC
Rated Power: 20A/2000W
Measuring Accuracy: 1.0 gradeTest range and display format:
Power Range: 0~2kW
within 1kW, display 0.0~999.9W;
above 1kW, display 1000~2000W.
Energy Range: 0~9999kWh
within 10KWh, display 0~9999Wh;
above 10kWh, display 10~9999kWh.
Voltage Range: 6.5~100V(display 6.50~99.99V)
Current Range: 0~20A(display 0.00~20.00A)Note:
This module is suitable for indoor, please do not use outdoor.
Applied load should not exceed the rated voltage or current.
Wiring order can’t be wrong.Hope this can help you.
Best regardsin reply to: D3806 – Need Instructions #6556Hello Brad,
Thank you for writing in.
Here is the instruction for you:
DATASHEET_091029
Hope this can help you.
Best regardsHello Yelena,
Thank you for writing in.
So sorry that since many products are with similar products, it is hard for us to ensure the product you are referring to.
Could you please tell us your order ID or the link of the product?
Looking forward to hearing from you.
Best regards -