    Dear Doug, the new inventory is on the way and the shipping item is always in 2 weeks. If you need a substitute, we also can resend it from China via EUB. Or maybe we can refund to you then you can reorder when the FBA inventory arrive.
    Looking forward to your reply.
    Best regards,
    DROK

    Drok
    Keymaster
    Post count: 2971

    Dear clark, yes, the meter was broken but the shunt is still okay. With using a separate power supply to power the meter, you can connect the shunt between the positive and the load.
    Any other questions, feel free to contact us.
    Best regards,
    DROK

    Drok
    Keymaster
    Post count: 2971

    Dear Doug, sorry about that. Due to all of this version are out of stock, so please tell us your order number, we can refund to you. Or any other suggestion??
    Looking forward to your reply.
    Best regards,
    DROK

    Drok
    Keymaster
    Post count: 2971

    Hi Pedroza, this LM2577 Step-up converter cannot meet your requirement. We have another step up converter that can meet your requirements,please click here to get more infor:
    http://www.amazon.com/gp/product/B00C9RM2QM/ref=as_li_tl?keywords=dc+converter

    Please note the output current is 4A max. If the power is not enough, you can connect them in parallel to gain power.

    Any other questions, please feel free to contact us.
    Best regards,
    DROK

    Drok
    Keymaster
    Post count: 2971

    Hi Pedroza, this LM2577 Step-up converter cannot meet your requirement. We have another step up converter that can meet your requirements,please click here to get more infor:
    http://www.amazon.com/gp/product/B00C9RM2QM/ref=as_li_tl?keywords=dc+converter

    Please note the output current is 4A max. If the power is not enough, you can connect them in parallel to gain power.

    Any other questions, please feel free to contact us.
    Best regards,
    DROK

    Drok
    Keymaster
    Post count: 2971

    Hi, sorry for the delay. If the leds come on as zeros, display “0”, this should be wired incorrectly. if the gauge display “1”, it should be overrange, more than 10A, the measurement range of the gauge is 10A.
    If you can please have the THIN black wire vacant, do not connect to anything, just connect the black wire to the battery’s negative lead and use the yellow wire as the (new) negative lead (wiring the meter in series).
    If you still have any other questions, don’t hesitate to write back to us.
    Best regards,
    DROK

    Drok
    Keymaster
    Post count: 2971

    Dear bernie, sorry for the delay. I have forward your message to our technicians, and yeah, the video is more helpful. Could you send us the video link?
    BTW, if it cannot work for you, reply us your order number and we will deal with it from the order directly.
    Thanks!

    Drok
    Keymaster
    Post count: 2971

    Hello, sorry for the delay. As the below image, the two spots next to “10-32v” “8-16v” mark on yellow circle, just connect the two spots to short circuit.
    090438_short-circuit

    And the unit is default at 10-32V.

    Any other questions, don’t hesitate to write back to us.

    Best regards,
    DROK

    Drok
    Keymaster
    Post count: 2971

    Hi, here is a 12v step-up module can meet your requirement. Any other questions, feel free to contact us.
    Best regards,
    DROK

    Drok
    Keymaster
    Post count: 2971

    Hi, you got this usb voltage converter, right? Sorry for the misunderstanding,not the “wire”, There are many dark blue lines for circuit conductive on the PCB board, you just need to knife to cut the line which the red arrow points to. When you cut off it, the circuit connect to the “button” will be cut off.
    090945_cutting
    Any other questions, write back to me, we will try our best to solve it.
    Best regards,
    DROK

    Drok
    Keymaster
    Post count: 2971

    Dear Doug and CJ, sorry for the delay. Did you buy this kind of Digital Thermometer? Thank you for your business and sorry for the trouble caused. As your description, the item maybe broken now. We are sorry about that, Could you tell me your order number? Maybe you can contact us from your order then we can deal with it directly.
    Beg your forgiveness and thanks for your understanding.
    Looking forward to hearing from you.
    Best regards,
    DROK

    Drok
    Keymaster
    Post count: 2971

    Hi clark, if you use a common power supply to power the meter and measured device, the meter was burnt. Usually the shunt need to series connected between negative of the power supply and the load to avoid being burnt when using a common power supply. So we recommend you to a separate, independent, isolated power supply.
    Thanks.
    DROK

    Drok
    Keymaster
    Post count: 2971

    Hi, did you get any readings when you didn’t extend the signal wires, and pleas make sure the current direction is from red wire to black wire. If the current direction is wrong then you cannot get any readings.
    Looking forward to your reply.
    Best regards,
    DROK

    Drok
    Keymaster
    Post count: 2971

    Dear Reed, how about this 12V to 5V usb converter, please click the product link to get more info.
    If you still have other questions, please feel free to contact us.
    Best regards,
    DROK

    Drok
    Keymaster
    Post count: 2971

    Dear Bob Sposato, below the wiring instruction:
    300166_wiring-instruction
    Any other questions, don’t hesitate to write back to us.

    Best regards,
    DROK