    Hello Don,

    Please check if it is this item, #2001712003, https://www.amazon.com/dp/B07B4CWKRJ/ref=as_li_tl?tag=proeng-20

    We are sorry we don’t have longer cable. If you need longer one, please use shield cable, or there is impact on measurement. Connector is XH2.54-3p.

    Best regards.

    Drok
    Keymaster
    Post count: 2971

    Hello Joel Cooke,

    Do you mean it can work before? what kind of load is connected?

    You need to upload picture  and then copay that URL .

    Or you can just send picture to service email: service@droking.com

    Wait for your reply.

    Best regards.

    Drok
    Keymaster
    Post count: 2971

    Hello Joel Cooke,

    May  I know how large the input voltage it is? Did you regulate voltage potentiometer clockwise or anticlockwise?

    If possible, would  you like to show us the display?

    Best regards,

    DROK

     

    Drok
    Keymaster
    Post count: 2971

    Hello Mike GUSTAFSON,

    You may reverse sensor connection.  Current reading with negative sign means that is charging status instead of discharging. Please change the current direction on sensor.

    Any more questions, please let us know.

    Besr regards,

    DROK

    Drok
    Keymaster
    Post count: 2971

    Hello,

    Is it this item? 200399

    Do  you mean the relay or  load doesn’t power on? Would you like to show us your connection so that we can check further?

    You can upload pictures here or send to service@droking.com

    Best regards,

    DROK

    Drok
    Keymaster
    Post count: 2971

    Hello Sebastian,

    If  input is below 5.3v, led can’t display accurately  voltage/current.  Did you check  output with other meter when input source is wall wart?

    To check it further, woluld you like to show us how it is by video?

    Does the preset voltage not change completely along with your adjustment?

    Best regards,

    DROK

     

    Drok
    Keymaster
    Post count: 2971

    Hello,

    It is glad the problem can be sloved.  For any more questions, please kindly let us know.

    Best regards.

    Drok
    Keymaster
    Post count: 2971

    Hello Chuck Bowers,

    Does the 12v source can offer enough power? If that UPS need at least 15w power, input power to 200217 should not be lower than 15W.

    Best regards.

    Drok
    Keymaster
    Post count: 2971

    Hello Bill Darron,

    Thanks for your supporting. But we are sorry  it can’t convert  stereo to mono.

    Best regards.

    Drok
    Keymaster
    Post count: 2971

    Hello Sebastian,

    Could you please tell us how much the input voltages respectively? Would you like to show us how it is by video?

    You can send video link here or send attachment to servcie@droking.com

    Best regards.

    Drok
    Keymaster
    Post count: 2971

    Hello Edward Johnson,

    Here is instruction for 2001712003, https://m.media-amazon.com/images/I/B1ubSSVdpyS.pdf

    Best regards.

    Drok
    Keymaster
    Post count: 2971

    Hello jeff,

    To check further, would you like to show us how it is and your connection? You can upload picture here or send it to service@droking.com

    Best regards,

    DROK

    Drok
    Keymaster
    Post count: 2971
    in reply to: SKU:200150 #41938

    Hello Bruce. S,

    Everything obeys the raw of conversion of energy. Now matter how you conver votlage, total power remains unchanges.

    If input source can only offer max 100w input power, it is impossible to get 113.4w output(54vx2.1a)

    And from 12v to 54v, there is a large votlage difference. It may cause more energy loss, so actual output may not be as what you set.

    Simple mode is regarding how to set output voltage/current, it is necessary operation.

    Best regards.

    Drok
    Keymaster
    Post count: 2971
    in reply to: SKU:200150 #41931

    Hello Bruce. S,

    Everything obeys the  law of conservation of energy. No matter how you change voltage, total power remains unchanged.

    If input source can only offer 100w max power , it is impossible for converter to output 113.4w (54vx2.1a)

    And from 12v to 54v, there is a large voltage difference. It may cause more energy loss. So actual output may not be as what you set.

    Simple mode is regarding how to program output votlage/current. it is necessary operation。

    Best regards,

    DROK

     

    Drok
    Keymaster
    Post count: 2971

    Hello Damon McInnes,

    Did you connect load? Without load, there is no load current.  And you can’t adjust current.

    If you don’t want to connect load in advance, please short the output to adjust current.

    Notice: This is available for buck converter only.

    Best regards,