Click Image for Gallery
Ask Question
It is a Digital Tester/Relay Controller, Operating voltage: DC 8 ~ 28V (limitation DC 8 ~ 32V), Load capacity: maximum load capacity of relay's normally open port: DC 0 ~ 30V / 10A, AC 0 ~ 250V / 10A; maximum load capacity of relay's normally closed port: DC 0 ~ 28V / 10A, AC 0 ~ 125V / 10A, Application:Suitable for electronic equipment,industrial equipment etc.
Parameters:- Operating voltage: DC 8 ~ 28V (limitation DC 8 ~ 32V)
- Consumption: 0.2W (turn off the display: 0.1W; relay-operating: 0.6W)
- Operating temperature: recommend -20°c ~ 60°c (limitation -30°c ~ 70°c)
- Measuring range: DC 0.0 ~ 99.9V
- Load capacity: maximum load capacity of relay's normally open port: DC 0 ~ 30V / 10A, AC 0 ~ 250V / 10A; maximum load capacity of relay's normally closed port: DC 0 ~ 28V / 10A, AC 0 ~ 125V / 10A
- Module size: 46 x 70 x 20mm
- Function 1:
- Voltage measurement: when select this function the relay will not operate, the display shows the current measurement voltage.
- Function 2:
- Charging monitoring: when the measured voltage is lower than the lower limit voltage, the relay operates; when the measured voltage is higher than the upper limit voltage, the relay disconnects.
- Function 3:
- Discharging monitoring: when the measured voltage is higher than the upper limit voltage, the relay operates; when the measured voltage is lower than the lower limit voltage, the relay disconnects.
- Function 4:
- Operate within the range: when the measured voltage is between the upper and lower limits, the relay operates; in other cases, the relay disconnects.
- Function 5:
- Operate outside the range: when the measured voltage is lower than the lower limit voltage, or the measured voltage is higher than the upper limit voltage, the relay operates; in other cases, the relay disconnects.
- Input interfaces:
- DC+: power supply positive
- DC-: power supply negative
- VIN: detecting port of measuring voltage
- Output interfaces:
- NO: relay's normally open interface. It will be hanging before the reply operates; it will short connect to COM after relay operates.
- COM: relay's common interface
- NC: relay's normally closed interface. It will short connect to COM before the relay operates; it will be hanging after the reply operates.
- Provide five functions to meet more application requirements.
- Can set the voltage's upper and lower limits.
- The measurement accuracy is ± 0.1V.
- Add the pull-off delay and break delay functions.
- All setting parameters can be automatically saved; power-down will not lose the settings.
- Redesigned power supply module to ensure the stability of the module over a wide voltage range.
- 1 x Voltage Monitoring Controller (Digital Tester)
Attributes | |
input voltage | 8~28V |
output current | 10A |
output power | -- |
output voltage | -- |
output ways | 1 |